Model: HSP-OCT1000
Product origin: China
Warranty: 1 Year
After-sales Service: Online Technical Support
Model: HSP-OCT1000
Product origin: China
Warranty: 1 Year
After-sales Service: Online Technical Support
The HSP-OCT1000 Optical Coherence Tomography for Ophthalmology is an integrated automatic artificial intelligence OCT system with both soft and hard capabilities, boasting complete independent intellectual property rights. It combines cutting-edge multi-image registration enhancement technology with industry-leading analysis techniques to offer a comprehensive solution for clinical diagnosis and treatment. This includes automated image capture, precise image analysis, intelligent and real-time cloud-based data sharing.
Main Features
1.Ultra-fast fundus signal acquisition
-80,000 times per second “second” acceleration technology, the scanning speed is greatly improved, helping to accurately capture different subdivision forms of fundus lesions in a shorter time and obtain high-quality images.
2.Diagram of the lesion
-It can be used for auxiliary diagnosis of 16 main fundus diseases.
Specification
| ITEM | HSP-OCT1000T | HSP-OCT1000S | HSP-OCT1000M |
| Type | SD-OCT | SD-OCT | SD-OCT |
| Light energy (cornea) | ≤750μW | ≤750μW | ≤750μW |
| Measurement characteristic | Axial resolution:5μmLateral resolution:20μm | Axial resolution:5μm Lateral resolution:20μm | Axial resolution:5μm Lateral resolution:20μm |
| Scanning characteristic | Maximum A-scan speed:≥20000times/second Scanning depth:2.3mm Maximum scanning range:12mm*9mm | Maximum A-scan speed:≥80000times/second Scanning depth:2.3mm Maximum scanning range:12mm*9mm | Maximum A-scan speed:≥55000times/second Scanning depth:2.3mm Maximum scanning range:12mm*9mm |
| Light Source characteristics | Central wavelength:840nm Optical power:≤750μW Refractive compensation range:-20D~+25D | Central wavelength:840nm Optical power:≤750μW Refractive compensation range:-20D~+25D | Central wavelength:840nm Optical power:≤750μW Refractive compensation range:-20D~+25D |
| Scanning mode | 5 kinds Large field of view: HD straight line, radiation six lines, local area: macula, optic disc | 7 kinds Large field of view: HD straight line, radiation six lines, area Local area: macula, optic disc Front section: HD straight line, radiation six lines | 7 kinds Large field of view: HD straight line, radiation six lines, area Local area: macula, optic disc Front section: HD straight line, radiation six lines |
| Scanning range | 12mm*9mm Complete the image acquisition of macula + optic disc at one time | 12mm*9mm Complete the image acquisition of macula + optic disc at one time | 12mm*9mm Complete the image acquisition of macula + optic disc at one time |
| Single line scan length | 12mm One scan macula+ optic disc | 12mm (Anterior segment 6mm) | 12mm (Anterior segment 6mm) |
| Pupil requirement | 2mm | 2mm | 2mm |
| Automatic pupil orientation | √ | √ | √ |
| Automatic pupil compensation | √ | √ | √ |
| Fundus image | Full pixel imaging technology based on high scanning speed | Full pixel imaging technology based on high scanning speed | Full pixel imaging technology based on high scanning speed |
| Focusing mode | Fully automatic | Fully automatic | Fully automatic |
| Software analysis | Large field analysis Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items Optic disc 6*6mm fundus image Cup-disc ratio Six lines Horizontal C/D Ratio Vertical C/D Ratio Optic cup area RNFL ring sweep thickness curve RNFL thickness topographic map TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items Macular 6*6mm fundus map Average thickness of the inner retina Average retinal thickness Macular fovea thickness ILM-RPE thickness topographic map ILM-RPE thickness grid RNFL thickness topographic map Retinal volume gridAnterior segment analysis (peripherals required) | Large field analysis Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items Optic disc 6*6mm fundus image Cup-disc ratio Six lines Horizontal C/D Ratio Vertical C/D Ratio Optic cup area RNFL ring sweep thickness curve RNFL thickness topographic map TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items Macular 6*6mm fundus map Average thickness of the inner retina Average retinal thickness Macular fovea thickness ILM-RPE thickness topographic map ILM-RPE thickness grid RNFL thickness topographic map Retinal volume gridAnterior segment analysis (peripherals required) | Large field analysis Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items Optic disc 6*6mm fundus image Cup-disc ratio Six lines Horizontal C/D Ratio Vertical C/D Ratio Optic cup area RNFL ring sweep thickness curve RNFL thickness topographic map TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items Macular 6*6mm fundus map Average thickness of the inner retina Average retinal thickness Macular fovea thickness ILM-RPE thickness topographic map ILM-RPE thickness grid RNFL thickness topographic map Retinal volume gridAnterior segment analysis (peripherals required) |
| User profile | √ | √ | √ |
| Integrated artificial intelligence | It can assist in thediagnosis of 16 majorophthalmic diseasesaccurately identify,segment andautomatically label thefocal area | It can assist in thediagnosis of 16 majorophthalmic diseases,accurately identify,segment andautomatically label thefocal area | It can assist in thediagnosis of 16 majorophthalmic diseases,accurately identify,segment andautomatically label the focal area |
| DICOM interface function | √ | √ | √ |
| Mode of operation | Fully automatic, manual operation | Fully automatic, manual operation | Fully automatic, manual operation |
Need a Turnkey Hospital Solution?
From Blueprint to Operation – Let’s Build Your Dream Hospital
Request Proposal