OCT Machine

Optical Coherence Tomography Machine
Optical Coherence Tomography Machine

HSP-OCT1000 Optical Coherence Tomography Machine

Model: HSP-OCT1000

Product origin: China

Warranty: 1 Year

After-sales Service: Online Technical Support

Share:

The HSP-OCT1000 Optical Coherence Tomography for Ophthalmology is an integrated automatic artificial intelligence OCT system with both soft and hard capabilities, boasting complete independent intellectual property rights. It combines cutting-edge multi-image registration enhancement technology with industry-leading analysis techniques to offer a comprehensive solution for clinical diagnosis and treatment. This includes automated image capture, precise image analysis, intelligent and real-time cloud-based data sharing.

Main Features

1.Ultra-fast fundus signal acquisition

-80,000 times per second “second” acceleration technology, the scanning speed is greatly improved, helping to accurately capture different subdivision forms of fundus lesions in a shorter time and obtain high-quality images.

2.Diagram of the lesion

-It can be used for auxiliary diagnosis of 16 main fundus diseases.

Specification

ITEMHSP-OCT1000THSP-OCT1000SHSP-OCT1000M
TypeSD-OCTSD-OCTSD-OCT
Light energy (cornea)≤750μW≤750μW≤750μW
Measurement characteristicAxial resolution:5μmLateral resolution:20μmAxial resolution:5μm
Lateral resolution:20μm
Axial resolution:5μm
Lateral resolution:20μm
Scanning characteristicMaximum A-scan speed:≥20000times/second
Scanning depth:2.3mm
Maximum scanning range:12mm*9mm
Maximum A-scan speed:≥80000times/second
Scanning depth:2.3mm
Maximum scanning range:12mm*9mm
Maximum A-scan speed:≥55000times/second
Scanning depth:2.3mm
Maximum scanning range:12mm*9mm
Light Source characteristicsCentral wavelength:840nm
Optical power:≤750μW
Refractive compensation range:-20D~+25D
Central wavelength:840nm
Optical power:≤750μW
Refractive compensation range:-20D~+25D
Central wavelength:840nm
Optical power:≤750μW
Refractive compensation range:-20D~+25D
Scanning mode5 kinds
Large field of view: HD straight line, radiation six lines, local area: macula, optic disc
7 kinds
Large field of view: HD straight line, radiation six lines, area
Local area: macula, optic disc
Front section: HD straight line, radiation six lines
7 kinds
Large field of view: HD straight line, radiation six lines, area
Local area: macula, optic disc
Front section: HD straight line, radiation six lines
Scanning range12mm*9mm
Complete the image acquisition of macula + optic disc at one time
12mm*9mm
Complete the image acquisition of macula + optic disc at one time
12mm*9mm
Complete the image acquisition of macula + optic disc at one time
Single line scan length12mm
One scan macula+ optic disc
12mm
(Anterior segment 6mm)
12mm
(Anterior segment 6mm)
Pupil requirement2mm2mm2mm
Automatic pupil orientation√√√
Automatic pupil compensation√√√
Fundus imageFull pixel imaging technology based on high scanning speedFull pixel imaging technology based on high scanning speedFull pixel imaging technology based on high scanning speed
Focusing modeFully automaticFully automaticFully automatic
Software analysis Large field analysis
Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items
Optic disc 6*6mm fundus image
Cup-disc ratio
Six lines
Horizontal C/D Ratio
Vertical C/D Ratio
Optic cup area
RNFL ring sweep thickness curve
RNFL thickness topographic map
TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items
Macular 6*6mm fundus map
Average thickness of the inner retina
Average retinal thickness
Macular fovea thickness
ILM-RPE thickness topographic map
ILM-RPE thickness grid
RNFL thickness topographic map
Retinal volume gridAnterior segment analysis (peripherals required)
Large field analysis
Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items
Optic disc 6*6mm fundus image
Cup-disc ratio
Six lines
Horizontal C/D Ratio
Vertical C/D Ratio
Optic cup area
RNFL ring sweep thickness curve
RNFL thickness topographic map
TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items
Macular 6*6mm fundus map
Average thickness of the inner retina
Average retinal thickness
Macular fovea thickness
ILM-RPE thickness topographic map
ILM-RPE thickness grid
RNFL thickness topographic map
Retinal volume gridAnterior segment analysis (peripherals required)
Large field analysis
Simultaneously covering macula and optic disc a total of 14 itemsLocal analysis – Optic disc 8 items
Optic disc 6*6mm fundus image
Cup-disc ratio
Six lines
Horizontal C/D Ratio
Vertical C/D Ratio
Optic cup area
RNFL ring sweep thickness curve
RNFL thickness topographic map
TSNI thickness grid of nerve fiber layerLocal analysis – macular 8 items
Macular 6*6mm fundus map
Average thickness of the inner retina
Average retinal thickness
Macular fovea thickness
ILM-RPE thickness topographic map
ILM-RPE thickness grid
RNFL thickness topographic map
Retinal volume gridAnterior segment analysis (peripherals required)
User profile√√√
Integrated artificial intelligenceIt can assist in thediagnosis of 16 majorophthalmic diseasesaccurately identify,segment andautomatically label thefocal areaIt can assist in thediagnosis of 16 majorophthalmic diseases,accurately identify,segment andautomatically label thefocal areaIt can assist in thediagnosis of 16 majorophthalmic diseases,accurately identify,segment andautomatically label the focal area
DICOM interface function√√√
Mode of operationFully automatic, manual operationFully automatic, manual operationFully automatic, manual operation