Tel.: + 86 13912963835

En
En

Infusion Pump

Injection Infusion Pump
Injection Infusion Pump

HSP-100II Single Channel Hospital Injection Infusion Pump

Model: HSP-100II

Product origin: China

Warranty: 1 Year

After-sales Service: Online Technical Support


Share:

Infusion pump HSP-100II with compact and lightweight design saves space and creates comfort during patient transport.

Main Features

1.Compact design

-The compact and light weight design saves space and are beneficial during patient transfer

-Large & colorful LCD display

2.Added safety

3.Free flow protection

-The built-in flow stop feature helps reduce the risk of accidental free flow when pump door is open.

4.Anti-bolus function

-Diminishes the volume of unwanted Bolus injected to the patient after removal of the occlusion cause.

-Anti-reverse rotation detection

5.Panel Lock

-The panel lock feature helps prevent unauthorized changes of any instrument setting

6.Versatile functions

-1300 history records

-Real time display

-RS232 interface (optional)

-90°rotation pole clamp convenient for horizontal bar, vertical IV pole & platform use

7.User-friendly operation

-Soft key design, easy to operate

-Load directly the last infusion rate and volume limit

-Adjustable buzzer volume

-Top indicator light reflects the operation status as well as alarm case

-Night mode to ensure good rest of patients

-Removable pump body for easy cleaning

Specification


Flow rate range0.1~1200 ml/h  Micro mode:0.1-99.9 ml/hr in 0.1 ml increments
Infusion modeRate mode,Drip mode, Time mode, Body weight mode   Optional: Intermittent infusion mode,Durg library mode
Volume to be infused
(VTBI)
0~9999ml
Volume Infused(∑)0~36000ml
Infusion accuracy± 5%
Applicable infusion setVarious brands of infusion set
KVOrate1~5ml/h
Bolus rate300~1200ml/h
Purge600ml/h
Air bubble detectionUltrasound sensor detection with four levels of air in line alarm adjustable
Occlusion pressure3 adjustable occlusion pressure settings: low,middle and high
Alarms

Visual and audible alarms: Door open, Air-In-Line, Occlusion, Infusion completion, infusion near over,

 Start reminder function, Low Battery Battery depleted, malfunction etc.

Computer InterfaceRs232
History records1300 history records
Power supplyAC:100~240V, 50/60Hz DC:12V±1V
BatteryRechargeable lithium polymer battery.7.4V,1900mAh
Can operate up to 6 hours at 25ml/h after fully charged.
Battery recharge time10h with power on. 3h with power off
Power consumption25VA
ClassificationClass l,type CF
Waterproof LevelIPX3
Mode of operationcontinuous
Dimensions145x100x120mm(length x width x height)
weight≤1.4kg
Operating conditionsl Temperature:5℃-40℃.l Relative humidity:10-95%.l Atmosphere pressure:86-106kPa
Storage conditionsl Temperature:-20℃~45℃l Relative humidity: 10~95% l Atmosphere pressure: 50kPa~106kPa
Transport conditionsl Temperature:-20~60℃l Relative humidity:10~95%℃l Atmosphere pressure:50~106kPa



HSP-100II Infusion Pump

Infusion pump HSP-100II with compact and lightweight design saves space and creates comfort during patient transport.
Inquiry Basket
(0)

Need a Turnkey Hospital Solution?

From Blueprint to Operation – Let’s Build Your Dream Hospital

Request Proposal