Endoscope Washer

Auto Endoscope Washer
Auto Endoscope Washer

Auto Endoscope Washer

Share:

Main Features

1.Full-coverage cleaning and disinfection

-A concave-mirror designed cover of the washing and disinfection chamber ensures the full immersion of all parts in the disinfectant solution during every operating cycle of the machine, including the endoscope surface and interior, disinfection chamber and its cover, piping and connectors for air/liquid inlets and leakage-detection.Circulating water flows maintain a continuous washing and disinfection of all the internal cavities of endoscopes and other components. There will be a minimum amount of bubbles even in continuous rinsing because the full coverage and immersion leaves no room for air (as shown in the following picture) .

2.Circulation washing pump

-Provide a continuous washing and disinfection of endoscope surfaces and all pipe interiors of air-inlet, water-inlet, biopsy and suction tubes, avoiding the formation of bacterial biofilm.

3.Sterile water rinsing

-A built-in sterile water filter prevents used and unclean rinsing water from contaminating the disinfected endoscopes.

4.Thermostatic control of disinfectant

-Thermostatic control ensures the cleaning and disinfection efficacy unaffected by the ambient temperature,as all disinfectants’performance declines as temperature drops. As found by Biotech-Germande:at room temperature (22°C), the population reduction of mycobacterium is between Log104 and Log105 after a 45 minutes’exposure in 2% glutaraldehyde solution. However,at 45°C,the reduction value could reach Log106 in less than 5 minutes, by using 0.15% glutaraldehyde solution.


Specification

Warning and Alarm IndicationsDescription and Processing
high temperatureDisinfectant temperature≥50°C, the machine will give an alarm to avoid damage to the endoscope.
Temperature sensor failureThe machine triggers an alarm to avoid damage to the endoscope.
disinfectant dischargefailureThe machine triggers an automatic alarm to avoid the use of invalid disinfectant if a discharge failure of disinfectant is detected.
endoscope leakageThe machine triggers an alarm to avoid damage to the endoscope if the air pressure on the endoscope is lower than the specified value.
low inflow water pressureThe machine automatically stops the operating cycle and triggers an alarm if the water inflow does not meet the requirement.
Insufficient cleaning enzymeThe machine gives a warning if insufficient cleaning enzyme is detected.
insufficient alcoholThe machine gives a warning if insufficient alcohol is detected.
Loose connector of the water inletThe machine will give a warning if it detects that the connector of the water inlet is loose.
cleaning enzyme injection failureThe machine will give a warning if a cleaning enzyme injection failure is detected
alcohol injection failureThe machine will give a warning if an alcohol injection failure is detected.
liquid discharge failureThe machine automatically stops the operating cycle and triggers an alarm if a liquid discharge failure is detected
indication to close chamber coverThe machine will trigger an alarm if an unclosed chamber cover is detected during the starting phase.

 