MD·JD-600S pulsating vacuum autoclave uses saturated steam as the sterilization medium, through the way of pulsating vacuum, the saturated steam can completely penetrate the surface of the article, and use the high-temperature saturated steam under high pressure to kill all microorganisms and their spores,The sterilization effect is reliable and it is the most effective method inphysical sterilization. The Impact of cold air on temperature is eliminated by means of pulsating vacuum exhaust, and finally vacuum dehumidification combined with jacket dryiing of sterilized items
Main Features
-Double door access type
-Horizontal sterilization chamber, rectangular section, European (GETINGE)
annular reinforcing rib jacket structure
-The bottom surface of the inner chamber adopts a sinking funnel process designtoensure the discharge of condensed water in the inner chamber;
- The materials that come into contact with steam, such as the inner tank and door
panel, are all S30408 stainless steel
-Unique pulsation vacuum process: negative pressure pulsation, trans-pressurepulsation
-The inner chamber can choose independent steam inlet design, multi-channel steaminlet design
-Pipeline system: 304 stainless steel sanitary pipe, clamp connection, all welds arewelded by automatic pipe welding machine;
-It has an automatic adjustment system for the drainage temperature, andthedrainage temperature is less than or equal to 55℃. (Water tank temperature control discharge)
-Air filter: The filtration precision is ≤0.22 microns, and the sterilizationratereaches 99.97%.
-The outer decorative cover is made of mirror frosted anti-fingerprint 304 stainless
steel, the surface is easy to clean.
Specification
| Chamber design press | -0.1~0.3Mpa |
| Chamber safety valve pressure | 0.28Mpa |
| Jacket design pressure | 0.3Mpa |
| Jacket safety valve pressure | 0.28Mpa |
| Set tempreture | 150℃ |
| Max working temp | 139℃ |
| Temperature uniformit | ±0.5℃ |
| Temperature control accuracy | 0-2℃ |
| Max working press | 0.28Mpa |
| Vacuum leak rates | ≤0.13KPa/min |
| Negative pressure pulse vacuum | Amplitude : -80~0KPa, Times : 1-99 |
| Pulsations across pressure | Amplitude : -80-80KPa ,Times : 1 |
| Ultimate vacuum | -96KPa |
| Positive pressure pulsation times | 1~3 |