Model: MD·JD-360S
Chamber volume: 360L
Certificate: CE / ISO
After-sales Service: Online technical support
Warranty: 1-Year
Model: MD·JD-360S
Chamber volume: 360L
Certificate: CE / ISO
After-sales Service: Online technical support
Warranty: 1-Year
Main features
-Double door access type
-Horizontal sterilization chamber, rectangular section, European (GETINGE)
annular reinforcing rib jacket structure
-The bottom surface of the inner chamber adopts a sinking funnel process designtoensure the discharge of condensed water in the inner chamber;
- The materials that come into contact with steam, such as the inner tank and door
panel, are all S30408 stainless steel
-Unique pulsation vacuum process: negative pressure pulsation, trans-pressurepulsation
-The inner chamber can choose independent steam inlet design, multi-channel steaminlet design
-Pipeline system: 304 stainless steel sanitary pipe, clamp connection, all welds arewelded by automatic pipe welding machine;
-It has an automatic adjustment system for the drainage temperature, andthedrainage temperature is less than or equal to 55℃. (Water tank temperature control discharge)
-The outer decorative cover is made of mirror frosted anti-fingerprint 304 stainless
steel, the surface is easy to clean.
Specification
| Sterilization Class | European Class B standard Autoclave |
| Capacity | 360 liters |
| Sterilizing temperature | 121°C,134°C |
| Pre-set mode | For the sterilization of instruments , sterile clothing , rubber stoppers , aluminum caps , raw materials , filters , culture media and other items with high sterilization requirements Sterilization |
| Dry procedure | Vacuum drying |
| Display | LCD screen , touch screen |
| Voltage | 380 V±10%, 50Hz |
| Printer and USB Port | Print by integrated thermal mini-printer and download from USB port ( Sterilizing data) |
| Chamber design press | -0.1~0.3Mpa |
| Chamber safety valve pressure | 0.28Mpa |
| Jacket design pressure | 0.3Mpa |
| Jacket safety valve pressure | 0.28Mpa |
| Set tempreture | 150℃ |
| Max working temp | 139℃ |
| Temperature uniformit | ±0.5℃ |
| Temperature control accuracy | 0-2℃ |
| Max working press | 0.28Mpa |
| Vacuum leak rates | ≤0.13KPa/min |
| Negative pressure pulse vacuum | Amplitude : -80~0KPa, Times : 1-99 |
| Pulsations across pressure | Amplitude : -80-80KPa ,Times : 1 |
| Ultimate vacuum | -96KPa |
| Positive pressure pulsation times | 1~3 |